Home/Blog/Air Quality Modelling for Cement Plants in India: AERMOD Guide
Back to Blog

Air Quality Modelling for Cement Plants in India: AERMOD Guide

June 24, 2026
24 min read
By DSTechnoverse
Air Dispersion Modelling

How air quality modelling for cement plants works in India: kiln, cooler and mill stacks, limestone mine and crusher dust, Indian emission standards, co-processing pollutants, cumulative mine and plant runs, a worked AERMOD example and common EIA review queries.

Air Quality Modelling for Cement Plants in India: AERMOD Guide

Quick answer: Air quality modelling for cement plants uses AERMOD to predict ground-level PM10, PM2.5, SO2, NO2 and CO from the kiln and raw mill stack, the clinker cooler, coal mill, cement mill and packing stacks, plus fugitive dust from the limestone mine, crusher, stockpiles, conveyors and roads. Each source type is set up differently, the captive mine and plant are assessed together, and the results are added to baseline and compared with NAAQS 2009 for Environmental Clearance or consent.

Air quality modelling for cement plants is one of the most common requests in Indian EIA work, because cement is an emission-intensive industry and plants are usually built next to their limestone reserves, close to villages and farmland. A typical integrated plant combines a few tall, hot stacks with dozens of low-level dust sources, and the two groups behave very differently in the atmosphere. Getting both right is what makes an AERMOD cement plant study defensible in front of an Expert Appraisal Committee (EAC), State Expert Appraisal Committee (SEAC) or State Pollution Control Board (SPCB).

This guide covers the emission points, standards, co-processing parameters, AERMOD setup per source type, mine and plant cumulative assessment, a worked example and common review queries, linking to our other guides rather than repeating them.

What Is Air Quality Modelling for Cement Plants?

Air quality modelling simulates what happens to pollutants after they leave a source. Using emission rates, stack parameters, hourly meteorology, terrain and building data, a dispersion model computes predicted concentrations at hundreds or thousands of receptor points around a plant.

For a cement facility, modelling turns an emission inventory into ground-level impact numbers. These predicted increments are added to measured baseline air quality and compared with the National Ambient Air Quality Standards (NAAQS) 2009 notified by the CPCB. The result forms the technical core of the air environment chapter in an Environmental Impact Assessment (EIA) report and of many consent applications.

It shows where the highest impact occurs, which sources drive it, and whether proposed controls and stack heights are adequate.

Why Cement Projects Need Dispersion Modelling

  • Environmental Clearance: Cement plants are listed in the schedule to the EIA Notification 2006, and the standard Terms of Reference issued by MoEFCC for the sector ask for predicted ground-level concentrations from the proposed and existing sources, with isopleths, the model used and the input data. See our guide to air quality modelling for Environmental Clearance for how this fits the EC process.
  • Consent to Establish and Operate: SPCBs often ask for modelling with Consent to Establish applications, expansions and fuel changes.
  • Stack design: Modelling checks whether a proposed chimney height gives adequate dispersion, alongside the CPCB formula approach described in our stack height calculation guide.
  • Layout and mitigation: It identifies the worst-affected directions and tests options such as enclosing transfer points, treating haul roads, upgrading filters or adding SNCR for NOx, and placing the green belt.
  • Public hearing: Transparent, standards-based results help answer questions from the community.

The Cement Process and Where Emissions Arise

Understanding the process flow is the first step to a complete source list. Most Indian plants use the dry process with a preheater and precalciner kiln, so the description below follows that route.

  1. Limestone mining: Limestone is drilled, blasted, loaded and hauled from a captive mine, often within a few kilometres of the plant.
  2. Crushing: A primary crusher, sometimes with a secondary crusher, reduces the limestone and feeds a covered or open stockpile.
  3. Raw meal preparation: Limestone is blended with correctives (laterite, bauxite, iron ore, clay) and ground in a vertical roller mill or ball mill. The raw mill uses hot kiln exhaust gas for drying.
  4. Pyroprocessing: Raw meal passes through a cyclone preheater and precalciner, then into the rotary kiln, where clinker forms at around 1,450 degrees Celsius. Fuel is coal, petcoke and, increasingly, alternative fuels.
  5. Clinker cooling: Hot clinker is cooled by air in a grate cooler. Part of the hot air returns to the kiln as combustion air and the excess is de-dusted and vented.
  6. Coal or petcoke grinding: A coal mill prepares solid fuel, often using cooler or kiln gas for drying.
  7. Cement grinding: Clinker is ground with gypsum and, for blended cements, fly ash or slag, in cement mills.
  8. Packing and dispatch: Cement is packed in bags or loaded in bulk onto trucks and rail wagons.

Each stage has one or more emission points. Ducted emissions pass through bag filters or electrostatic precipitators and leave through stacks. Undirected emissions escape from handling, storage and vehicle movement as fugitive dust.

Cement Plant Stacks: What to Model

The table below lists the stacks found in a typical integrated plant and what usually matters for each in the model.

StackMain pollutantsTypical characteristicsModelling notes
Kiln and raw mill (main stack)PM, SO2, NOx, CO, plus co-processing parametersTallest stack, large flow, moderate temperature when raw mill is onModel two operating modes: raw mill on and raw mill off (direct operation)
Clinker coolerPMLarge air flow, warm exhaustOften the second largest PM source; check whether vented through its own stack
Coal millPMSmall flow, low temperatureLow buoyancy, so building downwash can matter
Cement millsPMMedium flow, near ambient temperatureUsually several mills; group carefully, do not merge unlike stacks
Packing plant and silosPMSmall flow, short stacks or ventsMany small bag filter vents; may be modelled as point sources or grouped
Captive power plant or WHR boilerPM, SO2, NOxSeparate stack if a coal-fired CPP existsTreat as a separate point source group

The Kiln and Raw Mill Stack

The main stack carries kiln exhaust gases after the preheater. When the raw mill is running, the gas passes through the mill for drying, which lowers its temperature and increases moisture before it reaches the bag filter or ESP. When the raw mill stops, the plant runs in direct mode, the gas is cooled in a conditioning tower and goes straight to the stack, usually at a higher temperature and with different dust and SO2 levels.

A careful study models both modes, or at least justifies which one is worst case. A higher exit temperature improves plume rise but direct mode can also raise SO2 and dust concentrations, so the answer is not obvious without running both. Exit velocity, temperature and flow should come from design data for a new kiln or stack monitoring for an existing one, as explained in our guide to building an emission inventory for dispersion modelling.

Cooler, Coal Mill, Cement Mill and Packing Stacks

The cooler vent stack handles a large air volume, so even a low dust concentration translates into a significant mass emission rate. Coal mill, cement mill and packing stacks are shorter and cooler, and their plumes rise little. They sit next to tall structures such as the preheater tower, silos and mill buildings, so building downwash can control their near-field impact. BPIP-PRIME should be run for these stacks using the real building layout, as covered in our AERMOD building downwash guide.

Fugitive Sources in a Cement Plant and Captive Mine

Fugitive dust is often the larger contributor to ground-level PM10 near the boundary, even though stacks carry the larger share of SO2 and NOx. Cement plant fugitive dust modelling therefore deserves the same care as the stacks.

Fugitive sourceWhere it arisesSuggested AERMOD source type
Limestone mine (drilling, blasting, loading)Mine benches and facesOPENPIT or AREA, depending on pit geometry
Haul roads (mine to crusher)Unpaved roads carrying dumpersLine of VOLUME sources or LINE/AREA source
Primary and secondary crusherCrusher hopper and dischargeVOLUME source
Stockpiles (limestone, coal, additives, clinker)Open or partly covered yardsAREA or AREAPOLY source
Conveyor transfer pointsBelt-to-belt drops, stacker and reclaimerVOLUME sources at each transfer
Clinker handlingClinker silo and open storage, loadingVOLUME or AREA source
Plant roads and truck yardsPaved and unpaved internal roadsLine of VOLUME sources
Bulk loading and packingTruck and wagon loading spoutsVOLUME source

Limestone Mine and Crusher Dust

Limestone mine and crusher dust is usually estimated from activity data using emission factors such as those in US EPA AP-42 for drilling, blasting, loading, unpaved roads and crushing, adjusted for silt content, moisture, vehicle weight and control measures like water spraying. The full method for mines, including haul road treatment and pit geometry, is set out in our guide to air quality modelling for mining projects, so we do not repeat it here. For a cement project, the key points are that the mine and plant must share one meteorological file and one receptor grid, and that the haul road between the pit and the crusher is often the single largest PM10 source in the study.

Stockpiles, Conveyors and Clinker Handling

Wind erosion from stockpiles depends on the exposed area, material moisture, silt content and wind speed. Covered sheds reduce this sharply, so the inventory must reflect what is actually covered. Conveyor transfer points emit during each drop of material; enclosed transfers fitted with bag filters behave as small point sources instead. Clinker is dry and fine, so open clinker storage and loading can be a strong local source. Our explanation of AERMOD source types covers how to choose between point, area, volume, line and open-pit representations and how to set initial dispersion parameters.

Pollutants and Indian Emission Standards for Cement Plants

The pollutants modelled reflect both fuel combustion and the processing of mineral raw materials.

PollutantMain source in a cement plantNAAQS 2009 limits used for comparison
PM10Stacks, crushing, roads, stockpiles100 µg/m³ (24-hour), 60 µg/m³ (annual)
PM2.5Stacks and the fine fraction of fugitive dust60 µg/m³ (24-hour), 40 µg/m³ (annual)
SO2Pyritic sulphur in raw materials and fuel sulphur80 µg/m³ (24-hour), 50 µg/m³ (annual)
NO2High-temperature kiln combustion80 µg/m³ (24-hour), 40 µg/m³ (annual)
COIncomplete combustion, kiln upsets4 mg/m³ (1-hour), 2 mg/m³ (8-hour)

Stack emission limits for cement plants are set in Schedule I of the Environment (Protection) Rules, 1986. The cement entries were revised in 2016. In outline:

  • Particulate matter limits apply to the rotary kiln and also to the other process stacks such as the cooler, raw mill, coal mill, cement mill and packing plant.
  • SO2 limits for kilns are tiered according to the pyritic sulphur content of the limestone, so plants with high-sulphur limestone have a less stringent value than those with low-sulphur limestone.
  • NOx limits are tiered by kiln type and whether the kiln was commissioned before or after the 2016 amendment.
  • Cement plants with co-processing of wastes have a separate entry, notified under GSR 497(E) dated 10 May 2016, which adds further parameters.

Because these limits are tiered and have been amended, a modelling report should quote the exact values from the current notification and from the plant's consent conditions, which are sometimes tighter than the national standard. In the model, the emission rate for each stack is normally calculated either from the consented or design concentration multiplied by the normalised flow, or from measured data for an existing plant. Using the regulatory limit as the design concentration is a common conservative choice for a new kiln.

NOx is emitted mostly as NO and converts to NO2 in the atmosphere. Comparing NO2 with the NAAQS needs a conversion method such as ARM2 or OLM rather than assuming all NOx becomes NO2; see our guide to AERMOD NO2 modelling and NOx conversion.

Co-Processing Emissions: The Extra Pollutants

Co-processing means using wastes as alternative fuels or raw materials in the kiln. Common inputs include refuse-derived fuel from municipal solid waste, industrial hazardous wastes, plastics, tyres, spent solvents and biomass. Co-processing is encouraged in India because the kiln's high temperature, long gas residence time and alkaline environment can destroy many organic compounds and capture acid gases, while saving coal.

Co-processing does, however, introduce parameters that are not significant when firing only coal. Indian standards for plants with co-processing cover acid gases, organics, heavy metals and dioxins. In general terms:

  • Hydrogen chloride (HCl): From chlorine in plastics, PVC and some industrial wastes. Most is captured by the alkaline raw meal, but some passes to the stack, and chlorine also affects kiln operation through bypass systems.
  • Hydrogen fluoride (HF): From fluorine in some wastes and raw materials, largely absorbed in the kiln.
  • Total organic carbon (TOC): Indicates unburnt organics, and can also come from organic matter in the raw materials, not only the waste.
  • Heavy metals: Mercury, cadmium and thallium, and a group of other metals such as antimony, arsenic, lead, chromium, copper, manganese, nickel and vanadium. Most non-volatile metals bind into the clinker, but mercury is volatile and may leave with the exhaust gas.
  • Dioxins and furans: Can form if gas is held in the temperature window of roughly 200 to 450 degrees Celsius in the presence of chlorine and dust. Good quenching and stable operation keep emissions low.

For dispersion modelling, these parameters are treated like any other stack pollutant: an emission rate is derived from the applicable limit or measured concentration and the flow, and the model predicts ground-level concentrations. India has no NAAQS for HCl, HF, most metals or dioxins (lead is the exception, at 1.0 µg/m³ 24-hour and 0.5 µg/m³ annual), so results are usually compared with international health-based guideline values or carried into a health risk assessment, as described in our guide to air quality health risk assessment. Where a project co-processes large quantities of hazardous waste, a reviewer will expect at least a screening assessment of these parameters. For dedicated waste combustion plants, our guide to AERMOD for waste-to-energy and incinerators covers a similar pollutant set in more depth.

Modelling Approach for Each Source Type

An AERMOD cement plant model usually contains three groups of sources, and each needs its own treatment.

Kiln Stack Modelling

Kiln stack modelling uses POINT sources with height, inner diameter, exit velocity and exit temperature. Points to watch:

  1. Model raw mill on and raw mill off as separate scenarios, or as hourly varying emissions if the operating schedule is known.
  2. Use actual gas conditions for velocity and temperature, but derive the mass emission rate from normalised flow (Nm³/s) and concentration (mg/Nm³), corrected to the reference oxygen if the standard specifies it.
  3. Check the stack against BPIP-PRIME. Tall kiln stacks usually clear downwash, but the preheater tower can be close in height.
  4. For NO2, apply ARM2 or OLM and state the in-stack NO2/NOx ratio used.

Low-Level Process Stacks

Cooler, mill and packing stacks are also POINT sources, but their low buoyancy and nearby buildings make downwash the main issue. Run BPIP-PRIME with all significant buildings: the preheater tower, silos, mill houses, the cooler building and packing plant. Do not combine several stacks into a single equivalent stack unless they have very similar parameters and are close together, and say so in the report if you do.

Fugitive and Mine Sources

Fugitive sources are modelled as VOLUME, AREA, AREAPOLY, LINE or OPENPIT sources, with release heights and initial dimensions based on the physical geometry. Emission rates should vary with operating hours, for example mine activity during daytime shifts only, and wind erosion from stockpiles scaled with wind speed where the method allows. Particle size matters: PM10 and PM2.5 fractions should come from the emission factor method, and deposition can be included if the study asks for dustfall.

Meteorology, Terrain and Receptors

All sources share one AERMET meteorological file covering at least one year, with surface data that represent the site and upper-air or estimated profiles as accepted by the reviewer. Many projects also have one season of on-site monitoring from the baseline study. Our guide to meteorological data for air modelling in India explains the options. Limestone deposits often sit on plateaus or ridges, so AERMAP terrain processing with a suitable elevation dataset is normally needed; see terrain and land use data for AERMOD. The receptor grid should extend to at least the 10 km study area, with finer spacing near the boundary, the mine and the nearest villages, and discrete receptors at each baseline monitoring station and sensitive location.

Cumulative Assessment for Captive Mine and Plant

A cement plant and its captive limestone mine often go through separate EC processes, since mining has its own entry in the EIA schedule. But the air they affect is the same, and appraisal committees increasingly ask for a combined picture. A cumulative assessment for the captive mine and plant should:

  1. Include all plant stacks, plant fugitive sources, the mine, haul roads and the limestone transport route (road, conveyor or ropeway) in one model run.
  2. Add other significant sources within the study area, such as a neighbouring cement plant, a captive power plant or a stone crushing cluster, where emission data are available.
  3. Use baseline data that reflect the existing situation without double counting sources already included in the model.
  4. Report results at each receptor, not by adding the maximum of each source group, because the maxima occur at different places and times.
  5. Show source-group contributions at the worst-affected villages so that mitigation can be targeted.

Our guide to cumulative air quality impact assessment sets out the general method, including how to handle baseline and other industries in a cluster.

Worked Example: Integrated Cement Plant With Captive Mine (Illustrative)

The numbers below are illustrative only and are chosen to show the method. They do not describe any real plant and are not a statement of the applicable emission limits.

Project: A greenfield integrated plant with one kiln line of about 6,000 tonnes per day clinker, a captive limestone mine 3 km from the plant, and a covered conveyor from the crusher to the plant. Terrain is gently rolling. Two villages lie 1.5 km and 2.5 km from the boundary.

Step 1: Stack Inventory

StackHeight (m)Diameter (m)Exit temp (°C)Normalised flow (Nm³/s)Assumed PM (mg/Nm³)PM rate (g/s)
Kiln and raw mill1204.5120200255.0
Clinker cooler603.8110150253.75
Coal mill501.87530250.75
Cement mill 1452.28560251.5
Cement mill 2452.28560251.5
Packing plant301.24020250.5

The PM rate is the normalised flow multiplied by the concentration: for the kiln, 200 Nm³/s × 25 mg/Nm³ = 5,000 mg/s = 5.0 g/s. For the main stack, SO2 at an assumed 100 mg/Nm³ gives 20 g/s and NOx at an assumed 600 mg/Nm³ gives 120 g/s.

Step 2: Fugitive Inventory

Using AP-42 style factors with stated control efficiencies (water sprays on haul roads, enclosed crusher, covered limestone and coal sheds), the illustrative PM10 rates are: mine benches and loading 1.2 g/s as an open-pit source; unpaved haul road 2.0 g/s spread over 40 volume sources; crusher 0.4 g/s as a volume source; clinker and additive yards 0.6 g/s as area sources; transfer points 0.3 g/s in total; internal roads 0.5 g/s.

Step 3: Model Results

Pollutant and periodMax predicted increment (µg/m³)Location of maximumBaseline (µg/m³)Resultant at maximum (µg/m³)NAAQS (µg/m³)
PM10, 24-hour19.5Near haul road, 0.4 km from mine boundary6887.5100
PM10, 24-hour, at village 18.2Village 16876.2100
PM2.5, 24-hour5.1Near haul road3439.160
SO2, 24-hour6.43.2 km downwind of main stack1218.480
NO2, 24-hour (ARM2)14.83.2 km downwind of main stack2236.880

Step 4: Interpretation

The tall kiln stack controls SO2 and NO2, with maxima a few kilometres away where the plume touches down. PM10 is dominated by the mine haul road and is highest close to the source. At village 1, source-group analysis shows the haul road contributes over half of the increment. The illustrative mitigation is to pave or treat the first section of the haul road, increase spraying frequency and route trucks away from the village, which the re-run shows cuts the village increment by about a third. All results remain within NAAQS, but the margin for PM10 near the mine is the point the appraisal committee would focus on.

For a parallel example in another heavy industry, our steel plant AERMOD guide works through a secondary steel expansion with similar stack and fugitive groups, and our guide on averaging periods and NAAQS compliance explains how 24-hour and annual results should be reported.

Common Review Queries on Cement Plant EIA Air Modelling

Cement plant EIA air modelling is checked closely. The queries below come up again and again, and anticipating them saves a round of clarifications.

QueryWhat the reviewer wantsHow to address it
Fugitive sources missingMine, roads, stockpiles and transfer points in the model, not only stacksInclude a full fugitive inventory with emission factor workings
Raw mill off case not consideredWorst-case operating modeRun both modes and report the higher
NOx assumed as NO2 or conversion unexplainedClear NO2 methodState ARM2 or OLM, ratios and ozone data
Meteorology not representativeData source, period, wind rose comparison with site dataJustify the station or use processed site data, show wind roses
Terrain ignored on hilly sitesAERMAP elevations for sources and receptorsRun AERMAP and state the dataset
Mine and plant assessed separatelyCombined impact on shared villagesPresent a cumulative run with source groups
Co-processing parameters not addressedHCl, HF, metals, dioxinsScreening assessment against guideline values
Baseline double countingExisting sources counted in both baseline and modelExplain which sources are new and which are already in baseline
Isopleths unclearReadable maps with villages and monitoring stationsPlot on a base map at a sensible scale
Input files not providedAbility to check the modelSupply the input and output files on request

Our article on how accurate AERMOD is also helps when a reviewer asks how much confidence to place in the predictions.

Which Models and Tools Are Used?

AERMOD with AERMET, AERMAP and BPIP-PRIME is the standard tool for cement plant studies in India. CALPUFF is considered only for special cases such as long-range transport or persistent calms in complex valleys; our AERMOD versus CALPUFF guide explains when that is justified.

When Is Modelling Required for Cement Projects?

  • Greenfield plants: Within the EIA for Environmental Clearance.
  • Capacity expansion: When clinker or cement capacity increases, or a new kiln line or grinding unit is added.
  • Fuel and co-processing changes: Switching to petcoke, adding alternative fuels or co-processing hazardous waste.
  • Mine expansion: When the captive mine's production increases, often with a combined mine and plant run.

Cost and timeline depend on the number of sources, terrain, whether processed meteorology exists, and the scenarios requested. Our guide to AERMOD modelling cost explains what drives the effort, and EIA consultancies can read about outsourcing air dispersion modelling.

How DSTechnoverse Helps

DSTechnoverse carries out AERMOD air dispersion modelling for cement plants, grinding units and captive limestone mines across India, working directly for industry or as a white-label partner for EIA consultancies. We build the stack and fugitive inventory, run AERMET, AERMAP and BPIP-PRIME, model raw mill on and off cases, mine and plant cumulative scenarios and co-processing parameters, and deliver an EIA-ready report with isopleths, source-group tables and NAAQS comparison. Work is delivered remotely, with regional support for cement belts such as Indore and Madhya Pradesh, Hyderabad and Telangana and Gujarat. Contact us with your source list for a scoped proposal.

Frequently Asked Questions

What is the best air quality model for a cement plant in India?

AERMOD is the standard choice for cement plants because it is a regulatory model that handles tall kiln stacks, low-level mill stacks with building downwash, and fugitive area, volume and open-pit sources in one run. CALPUFF is considered only for special cases such as long-range transport or complex valley flows. The choice should be justified in the report.

Which pollutant is most critical in cement plant modelling?

PM10 is usually the most critical because fugitive dust from the mine, haul roads, crusher and stockpiles produces high concentrations close to the boundary. NO2 from the kiln is next, with SO2 important where limestone has high pyritic sulphur. CO is assessed but rarely limiting. Co-processing plants also assess HCl, HF, metals and dioxins.

Is air quality modelling mandatory for Environmental Clearance?

Yes. Cement plants are listed under the EIA Notification 2006 and the standard Terms of Reference ask for predicted ground-level concentrations from all sources, with isopleths, model details and input data. The appraisal committee and SPCB rely on these results, combined with baseline monitoring, when deciding on Environmental Clearance and consent.

Should the kiln be modelled with the raw mill on or off?

Both modes should be considered. With the raw mill off, the gas is usually hotter, which helps plume rise, but dust and SO2 concentrations can be higher. Running both scenarios and reporting the worse result, or using hourly varying emissions based on the operating schedule, answers a frequent reviewer query.

How is fugitive dust from the limestone mine and crusher modelled?

Emission rates are estimated from activity data using factors such as AP-42 for drilling, blasting, loading, haul roads and crushing, adjusted for silt, moisture and controls. The pit is modelled as an open-pit or area source, haul roads as a line of volume sources and the crusher as a volume source, all on the same grid as the plant.

Do co-processing plants need to model HCl, HF, metals and dioxins?

Where wastes are co-processed in significant quantities, reviewers increasingly expect at least a screening assessment. Emission rates are derived from the applicable limits or measured values and modelled like other stack pollutants. As India has no ambient standards for most of these, results are compared with international guideline values or used in a health risk assessment.

Should the captive mine and cement plant be assessed together?

Yes, where they affect the same villages. Even if the mine and plant have separate clearances, a combined run with source groups shows the total impact at each receptor and which source dominates. Results must be combined receptor by receptor, not by adding the separate maxima, because those occur at different places and times.

How large a study area is used for cement plant modelling?

A study area of 10 km radius around the plant is commonly adopted, matching the EIA baseline area, with the grid extended to cover the captive mine and transport route. Receptor spacing is finer near the boundary, mine and nearest villages, with discrete receptors at monitoring stations and sensitive locations such as schools and hospitals.

Can modelling help optimise stack height and green belt design?

Yes. Modelling tests whether a proposed stack height gives adequate dispersion and whether low stacks suffer from building downwash. Source-group results show the directions and distances where fugitive dust dominates, which guides enclosure of transfer points, haul road treatment and the placement of green belts where they will be most effective.

Share

Tags

air quality modelling cement industryair dispersion modellingAERMODEIAIndia

Explore More Articles

Discover more insights and updates from DSTechnoverse

View All Articles