Air Dispersion Modelling

How air dispersion modelling for thermal power plants works in India: tall stacks and multiple flues, wet FGD effects on plume rise, the 2015 emission standards, coal handling and ash pond dust, AERMOD vs CALPUFF, cumulative clusters, scenarios and review queries.

Air Dispersion Modelling for Thermal Power Plants in India

Quick answer: Air dispersion modelling for thermal power plants predicts how SO2, NOx, particulate matter and other emissions from tall unit stacks and from coal handling and ash areas spread over the surrounding area, so the project can show that ground-level concentrations stay within NAAQS 2009. In India the study is normally done with AERMOD inside the 10 km EIA study area, with CALPUFF added for long-range or coastal questions. The study has to reflect the 2015 emission standards, the effect of FGD on plume rise, stack height rules, fugitive dust and the cumulative load from neighbouring plants.

Air dispersion modelling for thermal power plants is a scientific technique that uses regulatory models such as AERMOD and CALPUFF to predict how emissions of SO2, NOx and PM travel, disperse and settle across the surrounding region. It estimates ground-level concentrations under the full range of local weather so that the project can be checked against CPCB and National Ambient Air Quality Standards (NAAQS) before it is approved, expanded or retrofitted.

This guide explains what a credible power plant study contains: unit stacks and multiple flues, the change in plume behaviour after a flue gas desulphurisation (FGD) retrofit, the emission standards notified in 2015, fugitive dust from coal and ash, terrain and long-range questions, cumulative clusters, the scenarios to run, an illustrative worked example and the queries appraisal committees usually raise.

What Is Air Dispersion Modelling for Thermal Power Plants?

For a thermal power plant, the model accounts for stack height, flue gas velocity, exit temperature, emission rates, terrain and hourly meteorology to calculate ground-level concentrations at thousands of receptor points.

The output shows whether each pollutant stays within NAAQS, where the maximum impact occurs and whether villages, forests or eco-sensitive zones are affected. If you are new to the method itself, our knowledge-base note on how AERMOD works covers the plume physics in plain terms.

For coal, lignite, gas and biomass-fired stations, this modelling is a core deliverable in the Environmental Impact Assessment (EIA) and a prerequisite for Environmental Clearance. Thermal power plants fall under item 1(d) of the schedule to the EIA Notification 2006, and the standard Terms of Reference for the sector ask for modelling of the main stack pollutants, fugitive dust from coal and ash handling, and cumulative impact where other plants are nearby. The general EC route is set out in our guide to air quality modelling for Environmental Clearance.

Why Is Dispersion Modelling Important for Power Plants?

Thermal power plants are among the largest point sources of air pollution in India, and their tall stacks spread the impact over a wide area rather than concentrating it at the boundary. Only a validated model can quantify that spread. Modelling demonstrates NAAQS compliance before construction or expansion, justifies stack height, predicts cumulative impact with neighbouring plants, supports decisions on FGD, ESP and low-NOx burners, and quantifies near-field dust from coal and ash handling, which often matters more to nearby villages than the stack. Weak modelling leads to queries at the Expert Appraisal Committee (EAC) stage or costly conditions later.

Which Pollutants Are Modelled from Thermal Power Stacks?

The pollutants of concern from combustion-based power generation are well defined, and each behaves differently in the atmosphere. A robust study models them individually against their respective averaging periods.

PollutantMain Source at PlantNAAQS 2009 (µg/m³)Modelling Concern
SO2Sulphur in coal and lignite80 (24-h), 50 (annual)Main driver of FGD decisions; long-range transport
NOx as NO2High-temperature combustion80 (24-h), 40 (annual)NOx-to-NO2 conversion method must be stated
PM10Fly ash carry-over, coal and ash dust100 (24-h), 60 (annual)Stack plus fugitive sources together
PM2.5Fine fly ash, secondary sulphate and nitrate60 (24-h), 40 (annual)Background often already high
COIncomplete combustion4 mg/m³ (1-h), 2 mg/m³ (8-h)Usually minor for coal units
MercuryTrace mercury in coalNo ambient standard in NAAQSReported as concentration or deposition where asked

The model compares the highest predicted concentrations for each averaging period against the standard. Because a tall stack disperses emissions widely, the maximum ground-level concentration from the stack often occurs several kilometres downwind, while the maximum from coal and ash dust sits close to the boundary. For NO2, the choice between total conversion, a fixed ratio and the ozone-limiting methods changes the answer substantially; see our guide to NO2 modelling and NOx-to-NO2 conversion. For how 24-hour and annual results should be read against the standards, see averaging periods and NAAQS compliance.

Emission Standards for Thermal Power Plants: The 2015 Notification

On 7 December 2015 the MoEFCC amended Schedule I of the Environment (Protection) Rules 1986 to tighten the particulate standard and introduce, for the first time, limits for SO2, NOx and mercury from coal-based thermal power plants. The limits depend on when the unit was installed. The values below are those commonly reported from the original notification and in Central Electricity Authority summaries; they are expressed in mg/Nm³ on a dry basis at 6 percent oxygen.

ParameterUnits installed before 31 Dec 2003Units installed 1 Jan 2004 to 31 Dec 2016Units installed from 1 Jan 2017
Particulate matter1005030
SO2600 (units below 500 MW), 200 (500 MW and above)600 (below 500 MW), 200 (500 MW and above)100
NOx600300 (later relaxed for this group)100
Mercury0.03 (500 MW and above)0.030.03

Three points need care when a modelling report quotes these numbers.

  1. The standards have been amended more than once. The NOx limit for units of the 2004 to 2016 group was later relaxed (450 mg/Nm³ is the figure generally reported), and the compliance deadlines have been extended several times.
  2. SO2 applicability now depends on location. Plants were placed into Categories A, B and C based on their distance from the National Capital Region, large cities, critically polluted areas and non-attainment cities, each with its own deadline. A further amendment in July 2025 kept the SO2 limit for Category A plants, left Category B plants to case-by-case decision by an expert committee, and exempted Category C plants from the SO2 limit, provided they meet the stack height criteria notified in 1990 (GSR 742(E)).
  3. The EC and consent conditions govern the project. An individual Environmental Clearance or consent may set a tighter limit or require FGD regardless of category.

Because these rules keep moving, a good report quotes the notification and amendment it relies on, by date, and models the emission rate the plant will actually be permitted to emit. Always check the latest Gazette text before relying on any limit. For the modelling, the standard turns into a mass emission rate: concentration multiplied by the normalised dry flue gas flow, converted to grams per second. That is the number the model needs, and it is also where many reports go wrong, typically by mixing actual and normal cubic metres or wet and dry flows. Our guide to building an emission inventory for dispersion modelling walks through those conversions.

Unit Stacks: Tall Stacks and Multiple Flues

Modern Indian coal stations usually discharge through tall concrete windshields, commonly 220 m to 275 m, each carrying one, two or more steel flues. A twin-flue stack serving two 660 MW or 800 MW units is typical. This configuration raises two modelling questions.

Stack height. The 1990 stack height notification for thermal power plants sets a fixed minimum height for larger units (220 m for units of about 200 MW up to below 500 MW, and 275 m for 500 MW and above) and a formula based on SO2 emission rate for smaller units. These values are recalled from the notification and should be checked against the current text for each project. The model then tests whether that height actually delivers acceptable ground-level concentrations given the terrain and meteorology. Our guides to stack height calculation under CPCB guidelines and the link between stack height and ground-level concentration cover the formula and the physics.

Multiple flues. Each flue can be modelled as a separate point source at its true location, or the flues can be merged into one equivalent stack when they are close together and run at similar conditions. Separate sources are conservative because they ignore the extra buoyancy that adjacent plumes gain when they merge. Merging, usually with an equivalent diameter chosen to preserve the total flow at the actual exit velocity, gives more realistic plume rise but needs justification. A sound report states which approach was used, why, and ideally shows that the conclusion does not change.

Building downwash. The boiler house, ESP and FGD absorber buildings are large, but a 275 m stack is normally well above the height where downwash matters. Downwash becomes important for shorter stacks, for auxiliary boiler and DG stacks, and for low-level sources near buildings. BPIP-PRIME is still run to demonstrate this rather than assume it; see building downwash and BPIP in AERMOD.

FGD Retrofits and Their Effect on the Plume

The FGD programme has changed the plume from many Indian stacks. Most installations are wet limestone systems, which scrub SO2 by spraying a limestone slurry into the flue gas. That process cools and saturates the gas, which has direct consequences for dispersion.

Plume ParameterBefore Wet FGD (illustrative)After Wet FGD (illustrative)Effect on Modelling
Exit temperatureAbout 130 to 140 °CAbout 50 to 60 °C (saturated)Buoyancy falls sharply
Exit velocityDesign value, often 20 to 25 m/sLower, unless the flue is resizedLess momentum rise, more chance of stack-tip downwash
MoistureModerateSaturated, visible wet plumeVisible plume is condensed water, not a compliance issue in itself
SO2 emission rateHighTypically reduced by 90 percent or moreMain reason for the retrofit
PMESP outlet levelCan include some carry-over of droplets and gypsum finesCheck the guaranteed outlet figure

The key point is that plume rise and emission rate move in opposite directions. The SO2 emission rate falls steeply, but the cooler, slower plume rises less, so the maximum ground-level concentration falls by less than the emission reduction and may move closer to the plant. For SO2 the net result is almost always a large improvement. For pollutants that the FGD does not remove, such as NOx and part of the PM, the lower plume rise can slightly increase ground-level concentrations compared with the pre-FGD case. A study for a retrofit should therefore rerun NOx and PM with the post-FGD exit conditions, not only SO2.

Several practical issues follow:

  • Use the post-FGD exit temperature and velocity in AERMOD. AERMOD does not add buoyancy from the latent heat released when water vapour condenses in the plume, so using the measured or design saturated temperature is the standard and slightly conservative approach.
  • Check stack-tip downwash. When exit velocity falls below about 1.5 times the wind speed at stack top, AERMOD's stack-tip downwash adjustment reduces the effective height. Keep it switched on, as the regulatory default does.
  • Model the bypass case if one exists. Some designs keep a bypass damper for absorber outages. If the consent allows bypass operation, the hours of bypass and the higher SO2 rate should be a separate scenario.
  • Use as-built flue dimensions if the flue is relined or a new wet stack is built.

Dry and semi-dry FGD systems cool the gas less and retain more buoyancy, so the change is smaller, but the same principle applies: model the exit conditions that will actually occur.

Coal Handling and Ash Pond Fugitive Dust Modelling

For people living near a power plant, dust from coal and ash often matters more than the stack. These sources are released at or near ground level, so their highest concentrations occur at or just outside the boundary. An EIA that models only the stacks will usually attract a query.

Fugitive SourceTypical AERMOD Source TypeEmission Basis
Wagon tippler or truck unloadingVolumeDrop-operation emission factor with control efficiency
Crusher house and transfer pointsVolume or point (if bag-filtered vent)Drop factors or vent concentration and flow
Conveyors (covered or open)Line of volume sourcesWind exposure of the open length
Coal stockyardAreaWind erosion and stacker-reclaimer activity
Ash pond or ash dyke dry beachArea or area-polygonWind erosion of exposed, dried ash
Fly ash silos and loadingPoint (vent) and volume (loading)Vent outlet concentration; loading drop factor
Haul and unpaved roadsLine of volume or area sourcesSilt content, vehicle weight and traffic, with watering control

Emission factors for these sources usually come from the US EPA AP-42 chapters on aggregate handling, wind erosion and roads, adjusted for local silt and moisture content and for the control measures committed in the Environmental Management Plan, such as dry fog systems, water sprinkling, covered conveyors, wind barriers and keeping the ash pond surface wet. The control efficiency assumed in the model must match the commitments in the EMP; reviewers do check. Ash pond wind erosion is particularly sensitive to the area assumed to be dry, so the report should state what fraction of the pond surface is taken as exposed and why.

Our guide to AERMOD source types explains when to choose point, area, volume and line sources, and the mining projects guide covers dust factors and haul roads in more depth, which apply equally to captive coal and ash transport.

Terrain, Meteorology and Long-Range Considerations: AERMOD vs CALPUFF

The choice of model depends on distance, terrain and the regulatory question. For most Indian EIA studies covering the standard 10 km study area, AERMOD is appropriate and expected.

  • AERMOD is the regulatory workhorse for near-field impacts up to about 50 km, handling terrain through AERMAP, building downwash through BPIP-PRIME and hourly meteorology through AERMET.
  • CALPUFF is a non-steady-state puff model suited to long-range transport beyond 50 km, persistent calms, coastal sea-breeze effects and complex wind fields in valleys.

Terrain. A 275 m stack sitting in a plain may still have its plume intercepted by hills a few kilometres away. Many Indian power stations sit near ridges, plateaus or river valleys, so elevated terrain receptors and the hill height scale are often decisive. Our guide to terrain and land-use data for AERMOD covers DEM selection and land-use parameters.

Meteorology. The EIA baseline normally includes an on-site meteorological station for one season, but AERMOD needs a full year of hourly data with upper-air information. Most studies combine site data with longer-term surface records and processed upper-air or prognostic data, and must justify representativeness. Note that NOAA's ISD surface data service, long used as a source for Indian stations, was retired in 2025; see NOAA ISD data for AERMOD after 2025 and our broader guide to meteorological data for air modelling in India.

When CALPUFF is worth it. Coastal plants where the sea breeze recirculates the plume, sites with frequent low-wind conditions in valleys, impacts on a national park or wildlife sanctuary more than 50 km away, and questions about secondary sulphate and nitrate particles. AERMOD models primary emissions only, so it cannot predict secondary PM2.5 formed from SO2 and NOx over hours to days. If the EAC asks about secondary PM or regional effects, CALPUFF with its chemistry options, or a photochemical model, is the right tool. The trade-offs are discussed in AERMOD vs CALPUFF.

Cumulative Impact in Power Plant Clusters

Several Indian regions host multiple large power stations within a few tens of kilometres of each other, along with mines, washeries, cement plants and smelters. Well-known examples include the Singrauli region, Korba, Chandrapur and the Talcher-Angul belt. In these areas the EAC normally expects a cumulative assessment rather than an increment from the project alone.

A cumulative study typically:

  1. Builds an inventory of existing and approved sources within the study area, and larger stacks beyond it whose plumes can reach the area, using consented limits or monitored values.
  2. Models the project and the other sources together on the same receptor grid and meteorology.
  3. Adds a background value from baseline monitoring, taking care not to double count sources already reflected in that background.
  4. Reports project increment, other-source contribution and total, for each pollutant and averaging period.

The double-counting point is important. Monitoring stations near existing plants already include their contribution, so adding both the monitored background and the modelled existing plants inflates the total. A defensible approach states clearly which sources are inside the background and which are modelled explicitly. See our guide to cumulative air quality impact assessment in India for the methods.

Scenarios in Air Dispersion Modelling for Thermal Power Plants

A single run at design conditions rarely answers every question. The scenarios below cover most EC, expansion and retrofit studies.

ScenarioPurposeKey Inputs
Proposed units at full load, standards metMain EC caseEmission at permitted limit, design exit conditions
Existing plus proposed unitsExpansion caseExisting stack data from monitoring; proposed at limit
Pre-FGD and post-FGDRetrofit justificationBoth sets of exit temperatures and velocities
FGD bypass or absorber outageAbnormal operation, if permittedUnscrubbed SO2 rate for the allowed hours
Worst-case coalFuel variabilityHighest sulphur and ash coal in the fuel supply agreement
Part loadPlume rise at reduced flowLower velocity and temperature, lower emission
Fugitive sources alone and combinedNear-field dustCoal handling, ash pond, roads with EMP controls
CumulativeCluster effectProject plus other sources plus background

Each scenario should be justified; the aim is to find the case that controls the result.

Worked Example: Illustrative 2 x 660 MW Plant with FGD

The numbers below are illustrative only, chosen to show the method. They do not represent any real plant.

Configuration. Two 660 MW supercritical units discharge through a single 275 m windshield with two steel flues, each 7.6 m internal diameter. Each unit produces about 2.2 million Nm³/h of dry flue gas at 6 percent oxygen. The site is in gently rolling terrain with a ridge 6 km to the north-east.

Step 1: Emission rates at the post-2016 limits.

  • SO2 at 100 mg/Nm³: 2.2 million × 100 mg = 220 kg/h, or about 61 g/s per unit.
  • NOx at 100 mg/Nm³: also about 61 g/s per unit.
  • PM at 30 mg/Nm³: about 18 g/s per unit.
  • Without FGD, burning coal that gives about 1,600 mg/Nm³ SO2, the rate would be about 980 g/s per unit.

Step 2: Exit conditions. Before FGD, gas leaves at about 135 °C and 22 m/s. After a wet FGD it leaves saturated at about 52 °C, and in the same flue the velocity drops to about 18 m/s because the gas has contracted.

Step 3: Buoyancy. Using the standard Briggs buoyancy flux, the pre-FGD flue gives roughly 800 m⁴/s³ at an ambient 30 °C, and the post-FGD flue roughly 175 m⁴/s³, a fall of about 78 percent. Because final plume rise scales roughly with the cube root of buoyancy flux in many conditions, the plume rises perhaps 35 to 45 percent less after FGD.

Step 4: Model runs. AERMOD is run with a year of processed meteorology, AERMAP terrain, a nested receptor grid to 10 km with extra receptors on the ridge, and both flues as separate point sources.

Step 5: Results (illustrative).

CaseMax 24-h SO2 increment (µg/m³)Max 24-h NO2 increment (µg/m³)Location of SO2 maximum
No FGD, 135 °C28.01.8Ridge, about 6 km NE
Wet FGD, 52 °C3.12.6Ridge, about 5 km NE

The SO2 maximum falls by about 89 percent while the emission rate falls by about 94 percent, because the lower plume rise brings the plume closer to the ridge. The NO2 maximum rises by about 45 percent, although it remains a small increment, because the emission is unchanged and the plume is lower. Adding an illustrative baseline background of 12 µg/m³ SO2 and 22 µg/m³ NO2, both totals remain well within the 24-hour standards of 80 µg/m³. The report would present these figures with contour maps, the ridge receptors highlighted, and a sensitivity run with merged flues to show that the conclusion does not depend on the flue treatment.

Step 6: Fugitive dust. A separate run of the coal stockyard, conveyors, crusher house and ash pond, with dry fog and sprinkling controls, shows its highest 24-hour PM10 increment just outside the southern boundary, close to the nearest village. That result, not the stack, drives the recommendation to add a wind barrier and green belt on that side.

Typical Review Queries from Appraisal Committees and SPCBs

Answering these common questions in the report saves a round of queries.

  1. Which emission standard and category have been assumed? Quote the notification and amendment by date and state the plant's category.
  2. Are the emission rates consistent with the flue gas flow? Show the conversion from mg/Nm³ to g/s, including the oxygen and moisture basis.
  3. Was the post-FGD exit temperature used? Reviewers notice when a retrofit study keeps the old 135 °C value.
  4. How were the multiple flues treated? Give the reason and, ideally, a sensitivity check.
  5. Is the meteorological year representative? Compare the site season with longer-term data, and show the wind rose.
  6. Were terrain and nearby hills included? Show AERMAP inputs and elevated receptors.
  7. Have coal handling, ash pond and road dust been modelled? With the EMP controls stated.
  8. How was NO2 derived from NOx? State the method and ozone data if used.
  9. Is the cumulative assessment complete? List the other sources and explain how double counting was avoided.
  10. Do the predicted maxima fall on sensitive receptors? Name villages, schools, hospitals and protected areas and give their predicted concentrations.

Our guide to common AERMOD mistakes covers many of the errors behind these queries, and how accurate AERMOD is helps frame uncertainty when a reviewer asks how much weight to place on the numbers.

When Is Air Dispersion Modelling Required?

Modelling is needed at several points in the life of a thermal power project: during EIA preparation for Environmental Clearance under the EIA Notification 2006; for Consent to Establish and Consent to Operate applications to the State Pollution Control Board; for capacity expansion or fuel change; for FGD, low-NOx or ESP retrofits where exit conditions change; and for stack height justification, including plants exempted from the SO2 limit on stack height grounds. Modelling early, before the layout is fixed, lets design changes be made cheaply.

Cost and Who Should Do the Work

Effort depends on the number of stacks, flues and fugitive sources, the number of scenarios, whether CALPUFF is needed, the quality of meteorological data and the terrain. A scoped proposal built around the plant configuration is more useful than a generic figure; our guide to AERMOD modelling cost explains the drivers. Results carry weight during appraisal, so the modeller must be able to defend every assumption. Many EIA consultancies outsource this module to a specialist; see how to outsource air dispersion modelling.

How DSTechnoverse Helps

DSTechnoverse carries out AERMOD air dispersion modelling for thermal power projects, working directly for plants or as a white-label partner for EIA consultancies, delivered remotely across India. We model unit stacks and multiple flues, pre and post FGD conditions, coal handling, ash pond and road dust as area, volume and line sources, terrain with AERMAP, downwash with BPIP-PRIME, and cumulative cases with background. Reports include emission calculations, scenario tables, NAAQS comparison and isopleth maps ready for EIA, EC and consent files. For regional context see Odisha and Chhattisgarh and Madhya Pradesh. To scope a study, contact us.

Frequently Asked Questions

What is the difference between AERMOD and CALPUFF for power plants?

AERMOD is a steady-state model best suited to near-field impacts within about 50 kilometres, including terrain and building downwash, and it is the normal choice for the 10 km EIA study area. CALPUFF is a puff model designed for long-range transport, calm winds, coastal sea breezes and secondary sulphate and nitrate. The choice depends on the domain, terrain and the question being asked.

Is dispersion modelling mandatory for Environmental Clearance in India?

Yes. Thermal power projects are listed in the EIA Notification 2006, and the standard Terms of Reference require air quality impact prediction for the main stack pollutants and fugitive dust. The modelling demonstrates that predicted ground-level concentrations of SO2, NOx and particulate matter, added to background, comply with NAAQS before clearance is granted.

Which pollutants are most important in thermal power plant modelling?

Sulphur dioxide, oxides of nitrogen and particulate matter, both PM10 and PM2.5, are the primary pollutants. Each is modelled against its NAAQS averaging periods. Carbon monoxide is usually minor for coal units, and mercury may be reported where the Terms of Reference ask, although NAAQS 2009 sets no ambient mercury standard.

How does an FGD retrofit change the dispersion model?

A wet FGD cools the flue gas to around 50 to 60 °C and usually lowers exit velocity, so plume rise falls sharply. SO2 concentrations still drop greatly because the emission rate falls by 90 percent or more, but the maximum may move closer to the plant. NOx and PM, which the FGD does not remove, can show slightly higher ground-level concentrations.

What emission limits should the model use for a coal power plant?

Use the limit that applies to the unit under the 2015 notification and its later amendments, which depends on installation date, unit size and, for SO2, the plant's location category. If the EC or consent sets a tighter limit, use that. State the notification date in the report and convert the concentration to a mass rate in grams per second.

Why is stack height important in dispersion modelling?

A taller stack lifts flue gases higher, allowing pollutants to dilute before reaching the ground, which lowers peak ground-level concentrations. Thermal power plants must meet the 1990 stack height criteria, which set fixed minimum heights for larger units. Modelling then checks whether that height achieves NAAQS compliance given the actual terrain and meteorology.

Do coal handling and ash ponds need to be modelled?

Yes, in most EIA studies. Wagon tipplers, crushers, conveyors, stockyards, ash pond dry beaches and haul roads release dust close to the ground, so their highest concentrations occur near the boundary and nearby villages. They are modelled as volume, area and line sources using emission factors adjusted for the control measures committed in the Environmental Management Plan.

How long does an air dispersion modelling study take?

Timelines depend on data availability and the number of scenarios. When representative meteorological, stack and layout data are ready, a focused AERMOD study can be completed in a few weeks. Cumulative assessments with many sources, or CALPUFF studies over complex terrain, need more time for data preparation, review and reporting.

Can modelling account for pollution from nearby existing sources?

Yes. Cumulative impact assessment models the new plant together with existing and approved sources nearby and adds a measured background concentration. The report must explain which sources are already reflected in the background and which are modelled explicitly, so that neighbouring plants are not counted twice and the total is realistic.

Can AERMOD predict secondary PM2.5 from power plant SO2 and NOx?

No. AERMOD models primary emissions only, so it does not predict sulphate and nitrate particles that form from SO2 and NOx over hours to days. Where an appraisal committee asks about secondary PM2.5 or regional effects, CALPUFF with chemistry options or a photochemical grid model is used alongside AERMOD.

Share

Tags

air dispersion modelling thermal power plantair dispersion modellingAERMODEIAIndia

Explore More Articles

Discover more insights and updates from DSTechnoverse

View All Articles