Quick answer: Air dispersion modelling services use regulatory models such as US EPA AERMOD to predict how emissions from stacks, vents, roads and open sources spread through the air, and what ground-level concentrations they produce at nearby receptors. In India the study is required for most EIA Terms of Reference, many Consent to Establish and expansion applications, stack height justification and complaint or NGT matters. A good study turns emission, meteorological and terrain data into concentration tables, isopleth maps and a NAAQS comparison that a State Pollution Control Board or Expert Appraisal Committee can check and accept.
Air dispersion modelling services help industries, developers and EIA consultancies answer one question before a regulator asks it: if this plant runs as designed, what will people around it breathe? This guide to air dispersion modelling in India covers when a study is needed, what it contains, which models are used, the data you supply, the process, deliverables, timelines, cost drivers and choosing a provider. If you only need the textbook definition, the knowledge base article What Is Air Dispersion Modelling? covers that in depth; this page is about getting a study done properly.
What Air Dispersion Modelling Is (In Brief)
Air dispersion modelling (also written air dispersion modeling, the US spelling used in EPA documents and much of the software) is the use of a mathematical model to simulate how a pollutant released from a source is carried by the wind and diluted by atmospheric turbulence. The model combines three sets of information: what is emitted and from where (the sources), the weather hour by hour (the meteorology) and the shape of the ground and nearby buildings (terrain and downwash). It then calculates concentrations at a grid of receptor points, typically for 1-hour, 8-hour, 24-hour and annual averaging periods.
The phrase air quality modelling is often used interchangeably, although strictly it is wider and can include photochemical and regional models. In Indian regulatory practice, when an EIA Terms of Reference asks for "air quality modelling" or "prediction of incremental ground-level concentrations", it almost always means a dispersion study of the project's own sources. Air pollution dispersion modelling and plume dispersion modelling are other names for the same work, the second one emphasising the plume rising from a stack.
For an explanation of the physics behind plume rise, stability classes and Gaussian distributions, read How an Air Dispersion System Works and How AERMOD Works.
When Air Dispersion Modelling Is Required in India
There is no single rule that says "every project must model". Instead, modelling is triggered by the approval route a project follows and by what the regulator asks for during that route. The common triggers are listed below.
| Trigger | Who asks | What the model must show |
|---|---|---|
| EIA Terms of Reference (Category A and B1 under the EIA Notification 2006) | MoEFCC Expert Appraisal Committee or SEIAA/SEAC | Incremental ground-level concentrations from the project, added to baseline monitoring, compared with NAAQS |
| Consent to Establish (CTE) or Consent to Operate (CTO) | State Pollution Control Board | That proposed stacks and controls will not cause NAAQS exceedance at nearby receptors |
| Expansion or modernisation | EAC/SEAC for EC amendment, SPCB for consent amendment | Combined impact of existing plus new sources, often against fresh baseline data |
| Stack height justification | SPCB, CPCB guideline checks | That the chosen height gives adequate dispersion, or that a taller stack is needed |
| Complaints, NGT or court matters | SPCB, CPCB, National Green Tribunal, joint committees | Source attribution and whether a facility can plausibly cause observed levels |
| Building and construction EC (real estate, townships, large commercial projects) | SEIAA/SEAC | Impact of DG sets, boilers or traffic, and sometimes construction dust |
| Cluster and cumulative studies | CPCB, SPCB, industrial estates | Combined contribution of many sources in an area |
EIA Terms of Reference
For projects listed in the schedule of the EIA Notification 2006, the standard and specific ToR issued by the appraisal committee usually require that air quality impacts be predicted with a suitable model and that the predicted increments be superimposed on baseline concentrations. This is the most frequent reason a client approaches an air dispersion modelling consultant. For a step-by-step treatment of the EIA chapter itself, see Air Dispersion Modelling for EIA in India and Air Quality Modelling for Environmental Clearance.
Consent to Establish and Consent to Operate
Many projects below the EIA threshold still need a dispersion study for consent. SPCBs increasingly ask for one when a unit installs a new boiler, thermic fluid heater, furnace or large DG set, or when a site lies close to habitation. The detail varies by state, and Air Quality Modelling for Consent to Establish covers what the boards typically expect.
Expansion Projects
For expansion, the question is whether the whole site still complies once old and new emissions are combined. A model of the existing site also lets you test layout and stack options before committing capital.
Stack Height Decisions
CPCB guidance gives formula-based minimum stack heights, for example based on sulphur dioxide emission rate or DG set capacity. Modelling goes further by showing the actual ground-level effect of different heights given local weather, terrain and buildings. The formulas are explained in Stack Height Calculation as per CPCB Norms and the modelling side in Stack Height and Ground-Level Concentration.
Complaints and NGT Matters
When residents complain about dust, smoke or odour, or a case reaches the National Green Tribunal, regulators and joint committees often need an objective estimate of what a facility contributes. A dispersion study read with monitoring data shows whether a source can plausibly cause observed levels, and needs careful documentation because opposing experts may examine it.
Real Estate and Construction EC
Large building and township projects needing Environmental Clearance are commonly asked to assess standby DG sets, central boilers and project traffic, on a smaller scale but with the same discipline. Environmental Consultant for Construction and Real Estate Projects covers the wider EC context.
What an Air Dispersion Modelling Study Includes
A complete air dispersion modelling study is more than a model run. The table below sets out the components a regulator expects to see, and what each one is for.
| Component | What it involves | Why it matters |
|---|---|---|
| Scope and pollutant selection | Agreeing sources, pollutants (PM10, PM2.5, SO2, NO2, CO and others such as HCl, NH3 or VOCs where relevant) and averaging periods | Avoids modelling the wrong thing or missing a pollutant named in the ToR |
| Emission inventory | Emission rates per source, from design data, stack monitoring, CPCB emission norms or emission factors | The model can only be as accurate as the emission rates |
| Meteorological data | At least one year of hourly surface and upper-air data, processed through AERMET | Drives transport and dilution; the largest source of uncertainty after emissions |
| Terrain and land use | Elevation data processed through AERMAP, surface roughness, albedo and Bowen ratio by sector | Affects plume impingement on hills and turbulence near the ground |
| Building downwash | Building dimensions processed through BPIP-PRIME | Short stacks near tall buildings can produce much higher local concentrations |
| Receptor grid | Cartesian or polar grid plus discrete receptors at villages, schools, hospitals and monitoring stations | Ensures the true maximum and sensitive locations are captured |
| Model runs and scenarios | Base case, expansion case, alternative stack heights or control options | Gives decision-useful comparisons, not one number |
| Post-processing | Maximum and ranked concentrations, isopleth maps, cumulative totals with baseline | Converts output into what the regulator reads |
| Reporting and QA | Methodology, assumptions, input listings, results, NAAQS comparison, conclusions | Makes the study reviewable and defensible |
The inventory step is covered in How to Prepare an Emission Inventory for Air Dispersion Modelling, receptor design in Receptor Grid Design in Dispersion Modelling, and source representation in AERMOD Source Types Explained.
Models Used in Air Dispersion Modelling Services
Model choice should follow the problem, not habit. In India most regulatory work is now done with AERMOD, but other models have their place.
| Model or approach | Type | Typical use in India | Limitations |
|---|---|---|---|
| AERMOD (US EPA) | Steady-state Gaussian plume with boundary-layer meteorology | Default for industrial EIA, CTE, expansion and stack height work within about 50 km | Not designed for long-range transport or strongly variable wind fields |
| AERSCREEN | Screening version of AERMOD | Quick conservative first check of a single source | Worst-case estimates, not suitable as the main EIA result |
| ISCST3 | Older Gaussian model | Still seen in some older Indian reports | Superseded by AERMOD as the US EPA preferred model |
| CALPUFF | Lagrangian puff model | Long-range transport, coastal sites, complex terrain, calm conditions | Heavier data and effort; needs a 3D wind field |
| CFD (computational fluid dynamics) | Numerical flow simulation | Very near-field problems: complex buildings, tunnels, enclosed yards | Computationally expensive; not a routine regulatory tool |
| Line-source and road models | Specialised dispersion for traffic | Highway and urban road projects | Limited to vehicle emissions |
AERMOD is the default for most air dispersion modelling services in India because it is the US EPA preferred model for near-field regulatory work, it handles point, area, volume, line and open pit sources, and appraisal committees are familiar with its output. It is supported by AERMET (meteorology), AERMAP (terrain) and BPIP-PRIME (building downwash), which are explained in Understanding AERMET, AERMAP and BPIP.
For a structured way to decide, read Choosing an Air Dispersion Model: AERMOD, CALPUFF, CFD or Screening and AERMOD vs CALPUFF for Indian EIA Projects. For the software packages that wrap these models, see Air Quality Modelling Software Used in India. Odour work has its own considerations, covered in Odour Dispersion Modelling in India.
Inputs You Need to Provide
Most delays come from missing or inconsistent inputs, not the modelling itself. Before requesting a quote, gather the following.
- Site location and layout. Coordinates of the site boundary and each stack, a plot plan showing buildings with heights, and the nearest habitations and sensitive receptors.
- Stack parameters. Height above ground, internal diameter at the exit, exit gas temperature and exit velocity or volumetric flow for each stack.
- Emission rates. Pollutant emission rates in grams per second or kilograms per hour, with their basis: design guarantee, stack monitoring, CPCB norm or emission factor. For an expansion, both existing and proposed sources.
- Fuel and process data. Fuel type, consumption, sulphur and ash content, and control equipment efficiencies, so emission rates can be checked or derived.
- Fugitive and area sources. Material handling, stockpiles, haul roads, open pits or storage tanks if they are in scope.
- Operating pattern. Hours per day and days per year, and whether sources run continuously or intermittently, such as standby DG sets.
- Baseline monitoring. Ambient air quality monitoring results from the EIA baseline season or from recent monitoring, with station locations.
- Regulatory documents. ToR letter, consent conditions or SPCB queries, so the study answers exactly what was asked.
Meteorological and terrain data are usually sourced by the modeller, although site meteorological station data from the baseline season should be shared if available. A fuller list, with the format each item should take, is in The AERMOD Input Data Checklist.
A Note on Meteorological Data in 2025 and Beyond
Indian studies have long relied on NOAA Integrated Surface Database (ISD) records for nearby airports. NOAA ended ISD in August 2025, so new studies need to use replacement datasets, on-site measurements or reanalysis-derived inputs, with the choice justified in the report. This is explained in NOAA ISD Stopped in 2025: Meteorological Data for AERMOD Now and Meteorological Data for Air Dispersion Modelling in India. AERMET processing is covered in AERMET Explained.
The Air Dispersion Modelling Process, Step by Step
A professional dispersion modelling consultant follows a predictable sequence, and knowing it shows where your input is needed.
- Enquiry and scoping. You share the project description, ToR or consent query and a source list. The provider confirms pollutants, averaging periods, scenarios and the model to be used, and identifies data gaps.
- Proposal and agreement. A scoped proposal sets out deliverables, assumptions and timeline. Agreeing scenarios now avoids rework later.
- Data collection and checking. Inputs are collected and checked for consistency: stack velocities that match flow and diameter, emission rates that match fuel and control efficiency, coordinates that fall inside the site.
- Meteorological processing. A representative year of surface and upper-air data is selected and run through AERMET, with surface characteristics set for the site. A wind rose is prepared and checked against local knowledge.
- Terrain and building processing. Elevation data are processed through AERMAP for every source and receptor, and building dimensions through BPIP-PRIME if downwash is relevant.
- Receptor design. A nested grid is laid out with finer spacing near the site and around expected maxima, plus discrete receptors at villages, schools and monitoring stations.
- Model runs. The base case and each scenario are run for all pollutants and averaging periods. Where NO2 is assessed, an appropriate NOx-to-NO2 conversion method is applied; see NO2 Modelling in AERMOD.
- Post-processing and comparison. Maximum incremental concentrations and their locations are extracted, added to baseline values and compared with NAAQS. Averaging period handling is covered in AERMOD Averaging Periods and NAAQS Compliance in India.
- Mapping. Isopleth maps are produced on a base map showing the site, receptors and monitoring stations; see How to Make AERMOD Isopleth Maps in QGIS.
- QA/QC and reporting. Inputs and outputs are cross-checked, and the report is written in a format that drops into the EIA chapter or consent application. How to QA/QC an Air Dispersion Modelling Report lists the checks.
- Regulatory support. The provider answers technical queries from the SPCB, SEAC or EAC and reruns scenarios if the committee asks for changes.
Deliverables From an Air Dispersion Modelling Study
You should receive a complete, reviewable package, not just a PDF of maps.
- Modelling report covering the project description, sources, emission inventory with basis, meteorological data source and justification, wind rose, terrain and land use treatment, receptor design, model selection and options, results, NAAQS comparison, conclusions and recommendations.
- Results tables giving maximum incremental concentrations for each pollutant and averaging period, their location and distance from the site, and the cumulative total with baseline.
- Isopleth maps for each pollutant and averaging period of interest, on a base map that a reviewer can relate to the site.
- Discrete receptor results at each village, sensitive receptor and monitoring station.
- Scenario comparison where stack heights, controls or layouts were tested.
- Model input and output files so that a reviewer or your own team can reproduce the run.
- EIA chapter text or consent annexure in the format your report requires, where this is in scope.
What each section should contain, and the level of detail regulators look for, is set out in What an Air Dispersion Modelling Report Should Contain. For help interpreting the outputs, see How to Read AERMOD Output.
Timelines for Air Dispersion Modelling Services
Turnaround depends far more on how quickly complete inputs arrive than on model run time. The indicative ranges below assume complete data at the start; they are planning guides, not commitments.
| Study type | Indicative working time after complete inputs |
|---|---|
| Single source screening or simple CTE study | A few working days |
| Standard EIA air chapter for one industrial site with several stacks | Around one to three weeks |
| Expansion with existing plus new sources and scenarios | Around two to four weeks |
| Large or multi-source sites with fugitive sources, complex terrain or downwash | Several weeks, scoped individually |
| CALPUFF or cumulative cluster studies | Longer, scoped individually |
Query responses after submission are usually quicker because the model is already built. The factors that stretch or shorten timelines are discussed in Turnaround Time for Outsourced AERMOD Studies.
What Drives the Cost of Air Dispersion Modelling
There is no fixed price for an air dispersion modelling study, and a quote that does not ask about your sources should be treated with caution. The main cost drivers are:
- Number and type of sources. A single boiler stack is very different from a steel plant with dozens of point sources plus fugitive emissions.
- Pollutants and averaging periods. Each pollutant and period adds runs, checks and maps.
- Scenarios. Existing, proposed and cumulative cases, plus stack height or control alternatives, multiply the work.
- Data readiness. If emission rates must be derived from fuel and process data, or stack parameters reconciled, effort rises.
- Meteorology. Sourcing and processing a representative year of data, or incorporating site station data, is a significant step, especially since the end of ISD.
- Terrain and buildings. Complex terrain and significant downwash add processing and checking.
- Model choice. CALPUFF or CFD studies require substantially more effort than AERMOD.
- Reporting format and support. A full EIA chapter with regulatory query support costs more than an annexure for consent.
These drivers are explained in more detail, with how to compare quotes, in Cost of Air Dispersion Modelling in India and How Much Does AERMOD Modelling Cost?. If you are weighing a licence against outsourcing, Is AERMOD Free? explains what is free and what you pay for.
How to Choose an Air Dispersion Modelling Provider
The provider you choose decides whether the study is accepted first time or comes back with queries. The full hiring process, including how to brief a consultant and what to put in the contract, is covered in AERMOD Consultant in India: How to Choose, Engage and Work With a Specialist. The short version is to check five things.
- Model competence. Ask which version of AERMOD and AERMET they run, how they set surface characteristics and how they handle NOx-to-NO2 conversion. Vague answers are a warning sign.
- Meteorological data approach. Ask what data source they will use now that ISD has ended and how they will justify its representativeness.
- Sample report. Review a redacted sample. Look for clear inputs, justified assumptions, readable maps and an honest NAAQS comparison.
- Regulatory familiarity. They should understand ToR wording, SPCB expectations and how EAC and SEAC members read air chapters.
- Support after submission. Confirm that query responses and reruns are included or priced clearly.
Common errors that lead to rejection are listed in 10 Common AERMOD Modelling Mistakes. EIA consultancies that want to subcontract the modelling, either openly or under their own name, should read How to Outsource Air Dispersion Modelling Without Losing Control of Quality and Scaling Your Consultancy With a White-Label Air Modelling Partner.
Air Dispersion Modelling by Sector
Each sector has its own sources, pollutants and regulatory focus. Sector guides on this site:
| Sector | Typical modelling focus | Guide |
|---|---|---|
| Thermal power | Tall stacks, SO2, NOx, PM, flue gas desulphurisation scenarios | Thermal Power Plants |
| Cement | Kiln and cooler stacks, raw mill, fugitive dust from crushing and handling | Cement Industry |
| Steel | Sinter, blast furnace, coke oven, many point and fugitive sources | Steel Plants |
| Mining | Open pit, haul roads, crushing, area and volume sources | Mining Projects |
| Pharmaceutical and chemical | Process vents, boilers, solvent VOCs, specific pollutants such as HCl | Pharmaceutical and Chemical Plants |
| Sugar and distillery | Bagasse boilers, incineration boilers, odour | Sugar Mills and Distilleries |
| Waste-to-energy | Incinerator stacks, dioxins, metals, acid gases | Waste-to-Energy and Incinerators |
| Roads and highways | Line sources from traffic, PM and NO2 | Road and Highway Projects |
For general manufacturing units, Air Dispersion Modelling for Industries in India is a good starting point. Where several industries share an airshed, Cumulative Air Quality Impact Assessment in India explains the approach.
Air Dispersion Modelling in India by Region
Regulatory practice, industrial clusters and meteorological data availability differ from state to state. AERMOD modelling services are delivered remotely across India, and the regional pages below explain the local context: the State Pollution Control Board, the main industrial areas and the weather data typically used.
- AERMOD Modelling in Bengaluru and Karnataka
- AERMOD Modelling in Hyderabad and Telangana
- AERMOD Modelling in Gujarat
- AERMOD Modelling in Mumbai, Pune and Maharashtra
- AERMOD Modelling in Delhi NCR
- AERMOD Modelling in Chennai and Tamil Nadu
- AERMOD Modelling in Odisha and Chhattisgarh
- AERMOD Modelling in Indore and Madhya Pradesh
Projects outside these regions are handled the same way, as site visits are rarely needed for modelling.
Doing It Yourself: AERMOD Software Options
Some EIA consultancies and in-house environment teams prefer to run their own AERMOD models, either to control timelines or to handle frequent small studies. US EPA distributes AERMOD and AERMET free, but running them from the command line takes time to learn and is easy to get wrong. That is why commercial interfaces exist, such as Lakes Environmental AERMOD View and Trinity Consultants BREEZE AERMOD.
DSTechnoverse offers two alternatives:
- AERMOD Studio, browser-based software that runs the real US EPA AERMOD and AERMET executables without a local install. Its current scope is point sources over flat terrain, which suits many CTE, boiler and DG set studies. A free demo is available. See AERMOD Software and AERMOD Online: How to Run US EPA AERMOD in a Browser.
- Personalised AERMOD software built for a firm's own workflow, report templates and source types. See AERMOD Software Provider in India.
Software does not replace judgement on meteorology, surface characteristics and receptor design, so many firms use it for routine work and outsource larger or contested studies.
Worked Example: Boiler Expansion at a Chemical Unit
The following example is illustrative. The numbers are invented to show how a study is structured and read; they are not from a real project.
The situation. A chemical unit in an industrial estate runs one 10 TPH coal-fired boiler on a 30 m stack. It plans to add a second 15 TPH boiler and needs an EC amendment and a CTE for expansion. The ToR asks for predicted incremental concentrations of PM10, PM2.5, SO2 and NO2 from the expanded unit, added to baseline.
Inputs. Stack parameters and emission rates are taken from the boiler supplier's guarantee and the existing stack monitoring report. A representative year of hourly meteorology is processed through AERMET, and terrain is processed through AERMAP. The boiler house and coal shed are entered in BPIP-PRIME because both stacks are close to them. Receptors are a nested grid out to 10 km plus discrete receptors at three villages and the four baseline monitoring stations.
Scenarios. Scenario A puts the new boiler on its own 30 m stack. Scenario B routes both boilers to a common 45 m stack.
Illustrative results, 24-hour averages (µg/m³):
| Pollutant | Max increment, Scenario A | Max increment, Scenario B | Highest baseline (98th percentile) | Total with Scenario B | NAAQS 24-hour |
|---|---|---|---|---|---|
| PM10 | 6.8 | 3.1 | 82 | 85.1 | 100 |
| PM2.5 | 3.4 | 1.6 | 41 | 42.6 | 60 |
| SO2 | 24.5 | 11.2 | 16 | 27.2 | 80 |
| NO2 | 14.0 | 6.5 | 24 | 30.5 | 80 |
Reading the result. In Scenario A the maximum occurs about 400 m north-east of the site, inside the zone affected by building downwash, and the PM10 total of about 88.8 µg/m³ is close enough to the standard that a committee may question margins. In Scenario B the taller common stack lifts the plume clear of the building wake, halving the increments and moving the maximum to about 1.2 km downwind, in open land rather than at the nearest village. The study recommends Scenario B, and the report includes maps for both scenarios so the appraisal committee can see why.
What this shows. The value of modelling here was not only to prove compliance but to compare two engineering options with evidence, which is what turns a dispersion study into a design tool.
Common Pitfalls That Delay Approval
Appraisal queries tend to repeat: emission rates that conflict with fuel data elsewhere in the EIA, meteorological data from a distant station with no justification, receptor grids too coarse to find the true maximum, downwash ignored for short stacks, baseline values added inconsistently, NO2 reported as total NOx, and maps without scale or receptor labels. Each is avoidable with a careful scope and a proper QA step. How accurate AERMOD is, and how to present uncertainty honestly, is covered in How Accurate Is AERMOD?.
How DSTechnoverse Helps
DSTechnoverse carries out regulatory AERMOD air dispersion modelling for EIA, Consent to Establish, expansion and stack height decisions, delivered remotely across India. We work directly with project proponents or as a white-label partner for EIA consultancies, and we document every input and assumption so the study can be reviewed and defended at SPCB, SEAC or EAC stage. For teams that prefer to run models themselves, AERMOD Studio runs real US EPA AERMOD and AERMET in the browser, and we also build personalised AERMOD software for firms. To scope a study or book a software demo, contact us.
Frequently Asked Questions
What are air dispersion modelling services? They are consultancy services that use regulatory models such as AERMOD to predict ground-level concentrations of pollutants from a project's sources. The provider collects emission, meteorological and terrain data, runs the model, compares results with NAAQS and delivers a report, maps and model files suitable for EIA, consent or expansion applications in India.
Is air dispersion modelling mandatory in India? It is not mandated by a single rule for every unit, but it is required in practice for most EIA projects through the Terms of Reference, and SPCBs often ask for it for Consent to Establish, expansion and stack height decisions. Complaint investigations and NGT matters frequently rely on it as well.
Which model is used for air dispersion modelling in India? AERMOD, the US EPA preferred near-field model, is the default for most industrial EIA and consent studies within about 50 km. CALPUFF is used for long-range, coastal or complex terrain cases, screening models for quick checks, and CFD for very near-field building or enclosure problems.
What is the difference between air dispersion modelling and air quality modelling? In Indian regulatory use they usually mean the same thing: predicting the incremental concentration from a project's sources. Strictly, air quality modelling is broader and can include regional, photochemical and forecasting models, while dispersion modelling focuses on how emissions from specific sources spread and dilute.
How long does an air dispersion modelling study take? Once complete inputs are available, a simple CTE study can take a few working days and a standard EIA air chapter commonly one to three weeks. Large multi-source sites, CALPUFF studies and cumulative assessments take longer. Missing emission or stack data is the most common cause of delay.
What data do I need to give a dispersion modelling consultant? You need site and stack coordinates, stack height, diameter, exit temperature and velocity, emission rates with their basis, fuel and control details, operating hours, building dimensions near stacks, baseline monitoring results and the ToR or consent query. The consultant usually sources meteorological and terrain data.
How much does air dispersion modelling cost in India? The fee depends on the number of sources, pollutants, scenarios, data readiness, terrain, model choice and the reporting format required. A scoped quotation after reviewing your source list is the only reliable figure. Our cost guide explains each driver and how to compare quotes fairly.
Can modelling help me choose a stack height? Yes. Modelling several stack heights shows how ground-level concentrations change, especially where building downwash is involved. This complements the CPCB formula-based minimum height and helps you choose a height that keeps concentrations well within NAAQS without unnecessary over-design.
Can I run AERMOD myself instead of hiring a consultant? Yes. AERMOD is free from US EPA, and interfaces such as AERMOD Studio, AERMOD View and BREEZE AERMOD make it easier to use. You still need sound judgement on meteorology, surface characteristics, receptors and QA. Many teams run routine studies in-house and outsource complex or contested ones.