Quick answer: A microbial contamination investigation is a structured, evidence-led search for the physical source of an organism found where it should not be. Confirm the result is real, identify the organism to species, rebuild the timeline, map every route into the product, review existing data, sample to test a specific hypothesis, type the isolates, find the harbourage, then apply CAPA aimed at that niche and prove it worked with a pre-defined effectiveness criterion.
Blaming the wrong source produces corrective actions that change nothing, a recurrence months later and a regulatory history that is harder to defend with every repeat. This guide covers how a contamination source investigation should run in pharmaceutical, food, cosmetic and nutraceutical plants, which organisms point to which sources, how to use Ishikawa and 5 Whys properly, and how to write CAPA that removes the niche, with an illustrative worked case.
What a Microbial Contamination Investigation Must Establish
A product contamination investigation has to answer four separate questions, and most weak investigations answer only one of them.
- Is the finding real? A laboratory artefact needs a laboratory CAPA, not a production one. The formal procedure for ruling out laboratory error is covered in our guide to out-of-specification microbiology investigation, and this article assumes that phase has been completed or is running in parallel.
- Where did the organism come from? This is the root cause: a physical location or a material, not a phrase such as "operator error" or "inadequate cleaning".
- How far does it reach? Which batches, lines, areas and periods are affected, and whether any distributed product is involved.
- What will stop it happening again, and how will we know? CAPA linked to the proven cause, with an effectiveness check defined before the CAPA is implemented.
These run on different clocks. Batch disposition is needed within days; the root cause may take weeks. Closing the root cause early to meet a deviation deadline usually closes it on the wrong answer.
When to Launch a Formal Investigation
A formal investigation, rather than a routine excursion record, is warranted for:
- Any sterility test positive, without exception. The specific procedure is set out in sterility test positive investigation.
- Recovery of a specified or objectionable organism in finished product, judged against the product's route and patient population (see objectionable organisms in non-sterile products).
- Any microbial recovery in a Grade A zone, and any recovery in Grade B above the action limit.
- An environmental result above the action limit, or a sustained adverse trend below it.
- A finished product out-of-specification result where laboratory error has been ruled out.
- Repeated recovery of the same organism at the same location, even within limits. Persistence indicates a niche.
- Consumer complaints indicating spoilage, off-odour, visible growth or pack swelling.
- Water system results above action limits or trending upward.
- A media fill or aseptic process simulation failure.
A location returning 2, 3, 3, 4 and 4 cfu against an action limit of 5 has breached nothing but is telling you something has changed; see microbiological trend analysis and SPC.
Regulatory Expectations: Annex 1, USP, Schedule M and FSSAI
Regulators do not prescribe one method, but they agree on what a credible investigation must show. The anchors below are paraphrased; work from the current published text.
| Reference | What it expects of a contamination investigation |
|---|---|
| EU GMP Annex 1 (revised 2022, in force from August 2023) | A documented contamination control strategy (CCS) covering all sources and routes; investigation of action-limit excursions and adverse trends; in Grade A any growth triggers investigation; organisms from Grade A and B identified to species, with their impact assessed; CCS reviewed in the light of investigation findings |
| USP <1116> Microbiological Control and Monitoring of Aseptic Processing Environments | Emphasises contamination recovery rates (the proportion of samples with any growth) rather than individual counts; rising recovery rates and recoveries in critical zones warrant investigation; identification supports source assessment |
| USP <1115> Bioburden Control of Nonsterile Drug Substances and Products | Risk-based control of bioburden in non-sterile manufacture, treating water, raw materials, personnel, equipment and the environment as contamination sources to be understood and controlled |
| Revised Schedule M (Drugs Rules, notified December 2023) | Introduces a pharmaceutical quality system with quality risk management, deviation handling, investigation of root cause and CAPA; its sterile products requirements align closely with WHO and EU GMP expectations |
| ICH Q9(R1) and ICH Q10 | Quality risk management tools for scoping and prioritising; a CAPA system that uses root cause analysis and verifies effectiveness |
| FSSAI: Schedule 4 of the Licensing and Registration Regulations, 2011; Food Recall Procedure Regulations, 2017 | Hygienic and sanitary practices, including water, cleaning and personnel hygiene, as the baseline against which a food contamination investigation is judged; a recall procedure where unsafe food has left the premises |
Two consequences follow. Under Annex 1, the investigation is not finished until the CCS is updated to recognise the route. Under revised Schedule M, Indian manufacturers can expect the same questions on rejected hypotheses and CAPA effectiveness that EU or US inspectors ask. Linking events to a documented risk assessment is covered in microbiological risk assessment using ICH Q9.
The Microbial Contamination Investigation, Phase by Phase
The phases below run broadly in sequence, although phases 1 to 5 often overlap in the first week. The single rule that matters most: the organism identity, the timeline and the flow map should all be established before a hypothesis is committed to, because each of them eliminates possibilities rather than confirming one.
| Phase | Objective | Key activities | Output | Typical time |
|---|---|---|---|---|
| 1. Contain and confirm | Protect product; rule out lab error | Quarantine; lab checklist; retain isolates | Confirmed event, holds in place | Days 0-3 |
| 2. Identify | Know the organism to species | MALDI-TOF, 16S rRNA or ITS sequencing | Species identity with confidence data | Days 1-5 |
| 3. Timeline | Find when it started and what correlates | Batch, line, shift, lot and maintenance history | Correlation table | Days 2-7 |
| 4. Flow map | List every physical route | Material, water, air, gas, people, equipment, cleaning | Annotated diagram | Days 3-7 |
| 5. Data review | Use what already exists | EM, water, cleaning, HVAC, maintenance records | Shortlist of credible routes | Days 3-10 |
| 6. Hypothesis sampling | Test specific propositions | Targeted swabs, water, air, raw material retains | Positive and negative evidence | Weeks 2-4 |
| 7. Typing | Link or separate isolates | Genotypic strain typing | Same strain or not | Weeks 3-5 |
| 8. Harbourage | Find the physical niche | Dismantling, inspection, intensive sampling | Located source | Weeks 3-8 |
| 9. CAPA | Remove the niche and the cause | Engineering, cleaning, material, procedure | Actions linked to findings | Weeks 4-10 |
| 10. Effectiveness | Prove it worked | Intensified monitoring to a set criterion | Closure decision | 1-3 months |
The points that most often decide the outcome, phase by phase:
- Contain and confirm. Quarantine potentially affected material and keep every isolate, plate and sample retain. Rule out laboratory error with a documented checklist; an artefact must be proven, not assumed.
- Identify. MALDI-TOF gives speed; 16S rRNA sequencing for bacteria or ITS for fungi where the result carries regulatory weight. See the microbial identification methods guide and, for moulds, fungal identification and mould speciation.
- Timeline. Add maintenance events, shutdowns, water sanitisation dates and HVAC work to the batch, line, shift and lot history. A surprising number of events begin within a fortnight of a maintenance intervention.
- Flow map. Draw the routes on the floor plan. A written list misses adjacencies, such as a drain beside an open hopper or one outlet used for both equipment rinsing and floor cleaning.
- Data review. Existing EM, water, cleaning and maintenance records often hold the answer. A facility flora library shortens the list immediately if the species has been banked from a location before.
- Hypothesis sampling. Include locations that should be positive if the hypothesis is correct and locations that should be negative. Sample in the production state that matters: during operation, after cleaning and after a shutdown give different answers.
- Typing. Species identity shows two isolates could be related; strain typing shows whether they are.
- Harbourage. Expect to dismantle equipment, cut out pipework or remove gaskets and culture them directly.
- CAPA. Remove the niche physically where possible; sanitisation alone rarely clears an established one.
- Effectiveness. Monitor against a criterion written before the CAPA. A single clean result proves nothing.
What the Organism Tells You About the Source
The organism identity is the strongest single clue in any contamination source investigation. The associations below are tendencies, not rules, but in practice they are reliable enough to set the first sampling priorities.
| Organism recovered | Most likely source | First places to look |
|---|---|---|
| Gram-negative rods: Pseudomonas, Burkholderia cepacia complex, Ralstonia, Sphingomonas, Stenotrophomonas | Water and wet surfaces | Purified water outlets, dead legs, hoses, rinse water, condensate, damp gaskets |
| Enterobacteriaceae: E. coli, Enterobacter, Klebsiella, Salmonella | Faecal contamination via water, animal-origin or botanical material, poor hygiene | Raw water and storage tanks, raw materials, hand hygiene, drains |
| Bacillus, Paenibacillus, Geobacillus (spore-formers) | Soil, dust, raw materials, air | Botanical and mineral raw materials, dispensing, dust-generating steps, cardboard and pallets |
| Moulds: Aspergillus, Penicillium, Cladosporium | Airborne spores, damp building fabric, HVAC | Filter housings, drain pans, ceiling voids, water-damaged walls, wooden pallets |
| Yeasts: Candida, Rhodotorula | Human origin or sugar-rich residue | Hands, syrup lines, sugar-rich product residues |
| Staphylococci (S. aureus, coagulase-negative) | Personnel | Gowning practice, glove integrity, interventions in critical zones |
| Micrococcus, Kocuria, Corynebacterium, Cutibacterium | Human skin flora shed into air | Airflow patterns, gowning, operator movement, intervention technique |
| Listeria monocytogenes | Persistent cool wet facility niche | Drains, conveyors, refrigeration units, floor joints |
| Clostridium and other anaerobes | Soil, animal material, anaerobic pockets | Raw materials, closed vessels, poorly drained process zones |
Gram-negative rods in a dry product usually entered with water, often a rinse or granulation fluid, not through the air. Skin flora in a Grade A zone points at interventions and airflow before gown fabric. In botanical products a high spore count is often inherent to the material, so the question becomes whether the incoming limit was right (see botanical raw material microbial contamination). Water-associated organisms that survive repeated sanitisation lead towards biofilm, covered in biofilm in water system contamination.
Root Cause Analysis for Microbial Contamination: Ishikawa, 5 Whys and Fault Trees
These tools organise thinking; they do not replace evidence, and each is harmful if used to reach a conclusion the data have not yet supported.
Ishikawa (fishbone) for contamination
Use the fishbone early, in phases 4 and 5, so no route is forgotten. The six categories translate as follows.
| Ishikawa category | Contamination questions |
|---|---|
| Material | Raw material lots, excipients, packaging components, incoming bioburden, supplier changes |
| Machine | Equipment design, gaskets and seals, dead legs, hollow parts, recent maintenance or modification |
| Method | Cleaning and sanitisation procedures, hold times, drying steps, aseptic technique, sampling procedure |
| Man (people) | Gowning, hand hygiene, interventions, new staff, carriers |
| Measurement | Laboratory error, method suitability, neutralisation of preservatives, incubation conditions |
| Mother nature (environment) | Water system, HVAC, air pressure cascade, condensate, building fabric, drains, season |
Each branch should end in a testable question, then be marked excluded, supported or untested with the evidence. An unmarked fishbone is decoration.
5 Whys for contamination
Use the 5 Whys once the physical source is located, to trace back to the system failure that allowed it. Used at the start, it locks in a single chain of reasoning too early. A good chain ends at something a CAPA can change:
- Why was Burkholderia in the product? Because the filler rinse water carried it.
- Why did the rinse water carry it? Because the outlet supplying it had a biofilm.
- Why was there a biofilm? Because a branch to that outlet was a dead leg longer than the design allowed.
- Why was the dead leg there? Because a recent modification capped a branch without returning it to the loop.
- Why was it not detected? Because the change control did not require a water system review or requalification sampling.
The fifth answer is the one that prevents the next event; the third is the one that fixes this one. Both belong in the CAPA.
For high-consequence events such as a media fill failure, a fault tree working down through "and" and "or" gates is worth the extra effort, because it exposes two small failures that only together produced the event.
Where Contamination Actually Hides
Harbourage sites are predictable. Sample these early.
- Dead legs in water and product pipework, where biofilm establishes undisturbed.
- Worn, cracked or wrongly sized gaskets, O-rings and seals. A compressed gasket with a hairline split is an almost perfect protected niche.
- Hollow rollers, conveyor chains and equipment legs that fill with water during cleaning and never dry.
- Drains and floor joints, particularly in cool wet areas, and the aerosol generated when they are cleaned with a hose.
- Condensate on ceilings, pipework and refrigeration units above open lines.
- Filler nozzles, dosing needles and internal surfaces of equipment rarely fully dismantled.
- Cleaning equipment itself: mops, brushes, buckets and hoses distributing organisms rather than removing them.
- Compressed air and nitrogen lines with condensate or poorly maintained point-of-use filters (see compressed air and gas microbiological testing).
- HVAC components: damp filter media, drain pans, duct interiors after water ingress.
- People: hands, hair, clothing and, in persistent cases, an asymptomatic carrier.
Worked Case: Burkholderia in an Oral Suspension (Illustrative)
The case below is illustrative. The plant, numbers and dates are constructed to show the method and the arithmetic; they do not describe a real client.
Situation. A non-sterile oral suspension plant runs two filling lines, Filler A and Filler B, from one purified water loop. Over eight weeks of routine release testing, six batches out of 40 show recovery of a Gram-negative rod on the specified-organism screen, although total aerobic counts remain within specification. MALDI-TOF identifies all six as Burkholderia cepacia complex, an organism generally regarded as objectionable in aqueous oral products.
Timeline
| Day | Event and evidence |
|---|---|
| Day 0 | Sixth positive batch; formal investigation opened; all batches from the eight-week window placed on hold |
| Day 1 | Laboratory checklist complete: negative controls clean, media growth promotion valid, no Burkholderia in lab EM. Lab error excluded |
| Day 2 | All six product isolates confirmed as B. cepacia complex by sequencing; isolates banked |
| Day 4 | Timeline built: positives began nine weeks after a change control that rerouted a water branch near Filler B |
| Day 5 | Correlation table shows positives concentrated on Filler B (below) |
| Days 6-14 | Targeted sampling: all purified water outlets, Filler B rinse hoses, nozzles, gaskets; controls at Filler A |
| Day 15 | Outlet POU-7, which supplies the Filler B rinse, positive for B. cepacia complex in four of eight samples |
| Day 20 | Pipe inspection finds a capped branch forming a dead leg about 1.2 m long upstream of POU-7 |
| Day 24 | Strain typing: dead leg swab, POU-7 water and all five Filler B product isolates indistinguishable; the Filler A isolate a different strain |
| Days 25-35 | Dead leg removed, loop sanitised, rinse hoses replaced, change control procedure revised |
| Days 36-95 | Effectiveness monitoring against pre-set criterion |
Step 1: does the line correlate?
Of the 40 batches, 22 ran on Filler A and 18 on Filler B.
- Filler A: 1 positive out of 22 = 1 / 22 = 0.0455, or 4.5%
- Filler B: 5 positives out of 18 = 5 / 18 = 0.2778, or 27.8%
- Check: 1 + 5 = 6 positives; 22 + 18 = 40 batches. Overall rate 6 / 40 = 15.0%.
The Filler B rate is about six times the Filler A rate (0.2778 / 0.0455 = 6.1). With numbers this small a ratio is not proof, but it is enough to direct sampling towards Filler B. Shift showed no pattern: three positives on day shift and three on night shift, from roughly equal numbers of batches.
Step 2: does the water point to one outlet?
During the targeted campaign, 48 purified water samples were taken across six outlets, eight per outlet.
- All outlets combined: 4 positives out of 48 = 4 / 48 = 0.0833, or 8.3%
- POU-7: 4 out of 8 = 50%
- The other five outlets: 0 out of 40 = 0%
POU-7 total aerobic counts across its eight samples were 35, 60, 140, 95, 20, 75, 110 and 45 cfu/mL. The sum is 35 + 60 + 140 + 95 + 20 + 75 + 110 + 45 = 580, so the mean is 580 / 8 = 72.5 cfu/mL. Against an alert level of 50 and an action level of 100 cfu/mL, five of eight samples exceeded the alert level (60, 140, 95, 75, 110) and two exceeded the action level (140, 110). Before the change control, POU-7 had averaged under 10 cfu/mL.
Step 3: is it the same organism?
Strain typing linked the dead leg swab, the POU-7 water isolates and all five Filler B product isolates. The single Filler A product isolate was the same species but a different strain, traced separately to a Filler A rinse hose stored coiled on the floor beside a drain, where the same strain was recovered. Typing turned what would have muddied the conclusion into a second, smaller finding with its own CAPA (hoses drained after use and stored off the floor).
Step 4: impact
Six batches were positive. The 13 Filler B batches that tested negative for Burkholderia were filled with water from the same outlet during the same period, so their negative release results were assessed against the sampling plan's sensitivity rather than accepted at face value. The impact assessment therefore considered all 18 Filler B batches, not only the five that failed.
Step 5: effectiveness
The criterion, written before the dead leg was removed, was: no Burkholderia in 30 consecutive batches across both fillers, POU-7 negative for B. cepacia complex in 12 consecutive weekly samples, and POU-7 total counts below the alert level in at least 11 of those 12.
Before CAPA, the plant's overall water recovery rate for any Gram-negative organism was 7 positives in 160 routine samples: 7 / 160 = 0.0438, or 4.4%. Over the effectiveness period it was 1 in 180: 1 / 180 = 0.0056, or 0.56%. That single recovery was a Sphingomonas from a different outlet, not Burkholderia, and was handled as a routine excursion. The criterion was met and the investigation closed, with the contamination control strategy updated to require water system review in every change control that touches the loop.
Impact Assessment: Establishing the Scope
Deciding how far the problem reaches is separate from finding the cause, and it is routinely scoped too narrowly to the batch that failed. Work through:
- Shared raw material lots. If the source was incoming, every batch from that lot is implicated.
- Shared equipment before cleaning. Carryover across a campaign is a common route.
- Same area and period. An airborne or environmental source affects everything made in that window.
- Same water system state, including water used for cleaning.
- Shared personnel or shifts, where the organism is human-derived.
- Distribution status. Distributed product turns quarantine into a possible recall with notification timelines.
- Health hazard at the level found for the real patient or consumer population. The same count can be trivial in an oral tablet and serious in an inhalation or ophthalmic product, and a qualified person should document that judgement.
Write these criteria into the procedure in advance; commercial pressure is strongest during the event.
CAPA for Microbial Contamination
Good CAPA for microbial contamination has three layers, and each should trace to a specific finding in the report.
| Layer | Purpose | Examples |
|---|---|---|
| Correction | Deal with the immediate situation | Batch rejection, sanitisation, replacement of a contaminated hose, removal of a gasket |
| Corrective action | Remove the proven root cause | Remove a dead leg, redesign a hollow part, change a raw material specification or supplier, fix a drainage fall |
| Preventive action | Stop the same system failure elsewhere | Change control requiring water system review, gasket replacement schedule, gowning requalification, flora library expansion |
Principles that separate working CAPA from CAPA that only looks complete:
- Physical before procedural. Retraining is appropriate when a practice was wrong. It is not a CAPA for a cracked gasket.
- Sanitisation is a correction, not a corrective action. It kills what it reaches; it does not reach an established niche.
- Validate what you change. A new disinfectant or contact time needs evidence that it works on the actual isolate and surface, as set out in disinfectant efficacy validation.
- Look sideways. If a dead leg caused this event, survey the rest of the loop and other loops built under the same change control.
- Write the effectiveness check first. Define locations, frequency, duration and the numerical criterion before implementation, so that closure is not negotiated after the fact.
Pharmaceutical, Food and Cosmetic Investigations: What Changes
Pharmaceutical contamination investigation. Sterile manufacture under Annex 1 puts weight on Grade A and B recoveries, aseptic process simulation and interventions (see cleanroom grades and EM limits explained). Non-sterile manufacture centres on objectionable organisms, water and raw material bioburden.
Food contamination investigation. Pathogens such as Salmonella and Listeria monocytogenes make it a consumer safety question with possible recall under the FSSAI recall regulations. Zoned environmental sampling helps locate harbourage; see food microbiology testing under FSSAI.
Cosmetics. Weakly preserved water-based products attract Pseudomonas and Burkholderia from water or bulk storage, and investigations often extend to preservative efficacy (cosmetic microbiology testing).
Nutraceutical and packaging units. Botanical powders bring spore-formers and moulds, so supplier qualification is often the main CAPA route.
Documenting It So It Survives Inspection
An investigation is judged on whether it found the cause and on whether the record shows it was capable of finding it. The report should:
- State every hypothesis considered, including those rejected, with the excluding evidence.
- Record the laboratory error assessment, identification method, database and confidence data, and typing method.
- Explain the sampling rationale: why those locations, at that time, in that production state.
- Show correlation data and arithmetic, not conclusions without numbers.
- Link every action to a specific finding, and report against an effectiveness criterion set in advance.
- Record batches considered and cleared, with reasons, and say plainly when no root cause was found.
Why Investigations Fail and Why Contamination Recurs
Most failed investigations we are asked to pick up formed a hypothesis on day one and spent the following weeks gathering support for it. The next most common failure is stopping at a plausible source rather than a proven one: "probably the water system" leads to sanitising the water system, and if the real harbourage was a cracked filler gasket, the contamination returns. Other recurring weaknesses are investigations led by the department whose performance is in question, no engineering input (many harbourages are worn seals, undrained cavities or the wrong gasket material), linking isolates at species level only, and default conclusions such as "operator error" or "inadequate cleaning", which are categories rather than causes.
If contamination returns after CAPA, either the harbourage was not found or it was not removed. Increasing sanitisation frequency defers the problem at rising cost. Recurrence within two to three weeks of sanitisation indicates a substantial reservoir close to the point of recovery.
How DSTechnoverse Helps
DSTechnoverse supports microbial contamination investigation for pharmaceutical, food, cosmetic, nutraceutical and packaging units across India, either at the start of an event or after earlier attempts have not stopped a recurrence. Work covers on-site investigation using the structured protocol above, targeted sampling campaigns, organism identification and strain typing through our microbial identification service, environmental monitoring and water system microbiology, statistical review of historical data to find when a problem began, and CAPA support aimed at the niche rather than the symptom. Our team works from Indore and travels to client facilities. Contact us to discuss an investigation.
Frequently Asked Questions
How long does a microbial contamination investigation take?
A straightforward case with a clear organism and an obvious route usually concludes in two to three weeks. A persistent, recurring contamination with an unlocated niche commonly takes two to three months, most of which is targeted sampling, typing and effectiveness monitoring. Batch impact decisions should not wait for the root cause; they are made within days on the evidence available.
Which root cause analysis tool is best for microbial contamination?
None works alone. Use an Ishikawa diagram early to make sure every route is considered, then test each branch with sampling and record review. Use the 5 Whys once the physical source is found, to trace back to the system failure that allowed it. Fault tree analysis suits high-consequence events such as media fill failures.
Why does the same contamination keep coming back?
Because the corrective action addressed the symptom rather than a physical harbourage. Sanitisation reduces the population it reaches but rarely removes an established niche such as a dead leg, a cracked gasket or a hollow roller. If an organism returns within weeks of sanitisation, a reservoir remains close to the point of recovery and has not been found.
Is strain typing worth the cost?
When the corrective action under consideration is expensive or disruptive, yes. Typing costs a fraction of a wrongly targeted equipment replacement or supplier change, and it can separate two unrelated problems that look like one, as in the worked case above. It is also the most persuasive evidence an inspector can see that the source was proven rather than assumed.
What if no root cause is found?
Document that honestly, list the hypotheses tested and excluded, and continue enhanced monitoring at the most probable locations with a defined review point. Regulators accept a rigorous investigation that reaches no definitive conclusion far better than a superficial one naming a convenient cause, provided the open questions and ongoing controls are clear.
What if the investigation points at a supplier?
Type the isolates before acting on it. A raw material and a facility niche can carry the same species coincidentally, and blaming a supplier on species-level evidence damages a relationship without fixing anything. Where typing confirms the material as the route, share the identification with the supplier and request their investigation, batch records and environmental data for the relevant period.
Should production continue during an investigation?
That is a risk decision for quality management based on the organism, the area, the product and how well the route is understood. It must be documented with a rationale and not made by production alone. Continuing on a line where the source is unknown usually requires added controls, such as increased testing or a temporary process change.
Does a food contamination investigation differ from a pharmaceutical one?
The method is the same, but the hazards and obligations differ. Food investigations more often involve pathogens such as Salmonella or Listeria, use zoned environmental sampling to locate harbourage, and may trigger recall duties under FSSAI regulations. Pharmaceutical investigations place more weight on species identification, cleanroom grades and objectionable organisms relative to the patient population.
If contamination has recurred despite corrective action, the source has not been found yet. DSTechnoverse runs structured contamination investigations with organism identification, strain typing and harbourage location, alongside industrial microbiological testing. Based in Indore, Madhya Pradesh, deploying to client facilities across India. Talk to our microbiology team.
If contamination has recurred despite corrective action, the source has not been found yet. DSTechnoverse runs structured contamination investigations with organism identification, strain typing and harbourage location. Based in Indore, Madhya Pradesh, deploying to client facilities across India. Talk to our microbiology team.